Technical

Reference Standards

Conformity to EU Directive 2011/65/EU (RoHS II directive)

The product range cable glands, fittings and accessories is produced in full compliance with the Directive 2011/65/EU “Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment” (RoHS).

EC/EN 60079-0

Explosive atmospheres
Part 0: General requirements

IEC/EN 60079-1

Explosive atmospheres
Part 1: Equipment protection by flameproof enclosures «d»

IEC/EN 60079-7

Explosive atmospheres
Part 7: Equipment protection by increased safety «e»

IEC/EN 60079-15

Explosive atmospheres
Part 15: Equipment protection by type of protection «n»

IEC/EN 60079-31

Explosive atmospheres
Part 31: Equipment dust ignition protection by enclosure «t»

IEC/EN 62444 (previously EN 50262)

Metric cable glands for electrical installation

IEC/EN 60423

Conduits for electrical purposes.
Outside diameters of conduits for electrical installations and threads for conduits and fittings

IEC/EN 60529

Degree of protection provided by enclosures (IP Code)

Certifications

Cable glands series A2F, A2FCNF, A2FPM, A2FPF, E1FW

ATEX Certificate: ETL25ATEX0489X
IECEx Certificate: IECEx ITS25.0006X

Accessories of Adapter, Reducer, Blanking Elements

ATEX Certificate: ETL25ATEX0489X
IECEx Certificate: IECEx ITS25.0006X

Dual Entry ‘Y’ Adapter & 90˚Adapter

ATEX Certificate: ETL24ATEX0474U
IECEx Certificate: IECEx ITS 24.0050U

Product quality assurance notification

ATEX (QAN):
IECEx (QAR):GB/ITS/QAR24.0010/00

Quality management system

Electrical equipment for gas (Excerpt Table 2 IEC / EN 60079-14 standard)

In accordance with UNI EN ISO 9001:2015 standard

Correspondence

Correspondence Technical Cable Gland
Correspondence between hazardous areas, substances and categories

The cable glands and accessories are made to be installed in the following areas:

  • Safe area: industrial execution
  • Zone 1 and 2, Zone 21 and 22: Ex db / Ex eb / Ex tb execution
  • Group I (mines), category M2 (I M2)
  • Group II (surface), category 2, potentially explosive atmospheres of mixture of air gases, vapours, mists, or dusts (II 2 GD)
  • Groups of gas IIA, IIB e IIC
  • Groups of dusts: IIIA, IIIB e IIIC


The classification of areas, foresees that hazardous areas are divided into zones based on the frequency and duration of the occurrence of an explosive atmosphere and the type of hazardous substances (liquids, gases and vapours or dust).

 

For more information refers to the following standards

  • IEC/EN 60079-10-1 Explosive atmospheres. Part 10-1: Classification of areas – Explosive gas atmospheres
  • IEC/EN 60079-10-2 Explosive atmospheres. Part 10-2: Classification of areas – Combustible dust atmospheres

EPL Apparatus Electrical installations in hazardous area

Electrical equipment for gas (Excerpt Table 2 IEC / EN 60079-14 standard)

EPL Electrical Cable Gland

For more information refers to the following standards

  • IEC/EN 60079-14 Explosive atmospheres. Part 14: Electrical installations design, selection and erection
  • IEC/EN 60079-17 Explosive atmospheres. Part 17: Electrical installations inspection and maintenance

EX Equipment

Subdivision based on the characteristics of the existing gases

EX Equipment Cable Gland

Gas and dusts temperature classes

Flameproof protection

An explosion may occur with the presence of 3 elements

IP degree of protection

IP Protection Cable Gland

Products ambient temperature

Products ambient temperature Cable Gland

Material Code

Material Code Cable Gland

EX MARKINGS ON EXGRIP PRODUCTS

The markings on cable glands, adaptors or plugs are very important as they allow the user to identify the article and manufacturer. Via the information on the markings, it is possible to check if the product meets the required application. Particular attention should be paid to certifications, relevant identification numbers, levels of protection and degree of protection IP.
The marking includes name of the manufacturer or its trademark, manufacturer article identification number, certification issuer’s name or marking and certificate reference. If it is necessary to indicate specific conditions of use, an “”X”” shall be placed after the certificate reference. A specific Ex marking shall be used for explosive gases and/or dust atmospheres.
Ex cable glands, blanking elements and thread adaptors need not be marked with a temperature class or maximum surface temperature.

Ex Grip Product Marketing Cable Gland

SERIES A2F CABLE GLANDS

SERIES A2FPM CABLE GLANDS

SERIES A2FPF CABLE GLANDS

SERIES A2FCNF CABLE GLANDS

SERIES E1FW CABLE GLANDS

SERIES ADP & RED OF ADAPTERS AND REDUCERS

SERIES PLG & PLD OF BLANKING ELEMENTS -STOPPING PLUGS

SERIES YADP OF DUAL ENTRY ‘Y’ ADAPTER

SERIES 90˚ADP OF 90˚ ADAPTER