IP67 & IP68
Certified Cable Glands
for Solar Power Plants
Built for extreme outdoor conditions. Engineered for solar EPC contractors, inverter manufacturers, and renewable energy infrastructure projects across India.




Outdoor Solar Installations Face Extreme Conditions
Standard cable glands often fail in solar environments due to continuous exposure to sunlight, dust, moisture, and temperature fluctuations.
UV Exposure
Continuous sunlight weakens low-grade plastic materials over time.
Monsoon Water Ingress
Improper sealing allows moisture penetration into electrical systems.
Dust Accumulation
Outdoor installations require high IP protection against fine particles.
Inverter Downtime
Cable failures can interrupt energy generation and plant efficiency.
Our Solutions
Exgrip Cable Gland Range for Oil & Gas / Refineries
A2F
Industrial Cable Gland
- For Indoor & Outdoor Applications
- Suitable for Unarmoured Cables
- Corrosion Resistant
- Easy Installation
- IP66 / IP68
E1FW
Flameproof Cable Gland
- Designed for Flameproof Enclosures (Ex d)
- Double Compression for Enhanced Safety
- Suitable for Armoured Cables
- High Temperature Resistance
- IP66 / IP68
Environmental Performance & Recommended Cable Glands
Designed for demanding outdoor renewable energy environments with reliable ingress protection for solar power infrastructure.
| Installation Environment | Environmental Challenge | Recommended Protection | Recommended ExGrip Model | Application Type |
|---|---|---|---|---|
| Rooftop Solar | UV exposure & rainwater | IP67 | A2F | Outdoor Solar Installation |
| Ground Mounted Solar Plant | Dust accumulation & moisture | IP68 | E1FW | Utility Scale Solar Farm |
| Solar Inverter System | Weatherproof cable sealing | IP67 / IP68 | A2F / E1FW | Solar Inverter Application |
| Outdoor Junction Box | Water ingress & corrosion | IP68 | E1FW | Renewable Energy Infrastructure |
| Control Panel | Dustproof cable protection | IP67 | A2F | Electrical Control Systems |
Certifications
Certified. Compliant. Trusted Globally.
ATEX Certificate
Determine whether the cable is armoured or unarmoured to select the appropriate cable gland type.
IECEx Certificate
Measure the outer diameter (OD) of the cable accurately and match it with the correct gland size using a gland chart.
PESO Approval
Select cable glands based on environmental conditions such as indoor, outdoor, wet, dusty, or hazardous areas.
IP Test Reports (IP66 / IP68)
Choose brass, stainless steel, or nylon cable glands depending on mechanical strength, corrosion resistance, and application needs.