Choosing the right cable gland size chart is a critical step in any electrical installation project. A cable gland serves as a secure entry and termination point where the cable connects to electrical equipment, providing proper sealing, strain relief, and mechanical protection. Selecting an incorrect gland size may result in loose connections, moisture entry, equipment damage, or serious electrical risks.

This comprehensive guide explains everything about cable gland size selection and reference charts, including:

  • Standard cable gland size chart in mm

  • Complete armoured cable gland size chart and unarmoured cable gland size chart

  • Detailed reference for double compression cable gland size chart

  • Special application guide for 3.5 core 300 sq mm cable gland size

  • Easy access to downloadable electrical cable gland size chart PDF

 

Whether you are dealing with single compression, double compression, armoured, or unarmoured cable types, this article will help you understand the correct cable gland type and choose the appropriate size with confidence for your installation requirements.

Cable Gland Size

The term cable gland size defines the specific cable diameter range that a gland is designed to firmly hold and properly seal. Selecting the correct size is essential to ensure reliable performance and long-term safety in any electrical system.

Choosing the appropriate cable gland size guarantees:

  • Mechanical protection – protects the cable from damage caused by tension, vibration, or twisting.

  • Environmental sealing – prevents dust, moisture, and gases from entering electrical enclosures.

  • Electrical safety – ensures correct earthing continuity and shielding, especially in armoured cables.

 

Cable glands are typically measured in millimeters (mm) and correspond to the outer diameter (OD) of the cable. For instance, if the cable OD is 20 mm, the selected cable gland size must accommodate a sealing range such as 18–22 mm to ensure proper grip and sealing.

Selecting the wrong cable gland size can lead to improper fitting, ineffective sealing, and potential electrical failures. For this reason, engineers and installers always consult a reliable cable gland size chart before proceeding with installation.

Cable Gland Type and Size

Choosing the correct cable gland type and size is essential for ensuring safety, durability, and long-term performance in electrical installations. The selection process should be based on factors such as application type, cable construction, operating environment, and required protection level.

Various cable gland types are specifically engineered for indoor use, outdoor environments, hazardous zones, and flameproof systems. Understanding the differences helps in selecting the most suitable solution for each project.

Below are the most widely used cable gland types:

Single Compression Cable Glands

Single Compression Cable Glands are primarily intended for unarmoured cables. These glands provide sealing at a single compression point, ensuring adequate strain relief and environmental protection.

They are generally:

  • Used for unarmoured cables

  • Designed to provide basic sealing and strain relief

  • Suitable for indoor and controlled environments

 

This type is commonly chosen for standard electrical installations where heavy-duty protection is not required.

Double Compression Cable Glands

Double Compression Cable Glands are specifically designed for armoured cables. Unlike single compression types, they seal both the inner bedding and the outer sheath of the cable.

Key features include:

  • Designed for armoured cables

  • Provides sealing at both the inner and outer sheath of the cable

  • Offers extra mechanical strength and enhanced weatherproofing

  • Preferred for outdoor and hazardous areas

 

These glands are widely used in demanding industrial environments where additional protection and durability are required.

Brass Cable Glands

Brass Cable Glands are manufactured using high-quality brass material to ensure strength and longevity. They are commonly used in industrial applications due to their corrosion resistance and mechanical durability.

Important characteristics:

  • Made of high-quality brass material for durability

  • Suitable for both armoured and unarmoured cables

  • Corrosion-resistant and ideal for industrial applications

 

Brass glands are considered a reliable solution for heavy-duty electrical installations.

Flameproof / A2F Cable Glands

Flameproof / A2F Cable Glands are specially engineered for use in hazardous zones where explosive gases or flammable environments may be present.

They are:

  • Specially designed for hazardous zones

  • Engineered to prevent flame propagation inside equipment

  • Commonly used for unarmoured cables in flameproof enclosures

 

These glands play a critical role in ensuring safety in high-risk industrial sectors.

Cable Gland Size Chart PDF

For practical on-site reference, many engineers prefer carrying a cable gland size chart PDF. A portable PDF format makes it easier to verify sizing during installation, inspection, maintenance, or procurement activities.

Several versions are available depending on project requirements, including:

  • Electrical cable gland size chart PDF – covers both armoured and unarmoured cable sizes

  • Double compression cable gland size chart PDF – designed for hazardous areas, outdoor installations, and heavy-duty applications

  • Armoured cable gland size chart PDF – specifically for armored cables with metallic sheathing

 

Downloading the detailed cable gland size chart PDF allows professionals to select the correct cable gland size efficiently, eliminating errors and reducing installation risks.

Cable Gland Size Chart Types / Series

Cable glands are generally categorized based on whether the cable construction is unarmoured or armoured. Each classification follows a specific series, with its own cable gland size charts and defined clamping ranges.

Because armoured and unarmoured cables differ in structure and protection requirements, their corresponding gland types are also designed differently. As a result, the size chart types and series vary to ensure proper sealing, mechanical grip, and long-term performance.

Understanding the correct cable gland size chart types / series helps in selecting the appropriate gland that matches the cable diameter and application conditions without compromising safety or efficiency.

Cable Gland Size Chart for Unarmoured Cable :

Size Selection Chart For Unarmoured Cable
Note: These gland sizes may be one size up, please measure actual cable size and compare with the min/max sizes in the appropriate glands group.
Cable Size (mm²) No. of Cores UNARMOURED Cable Size (mm²) No. of Cores UNARMOURED
Approx. Min Cable Outer Approx. Max Cable Outer A2F Series – Single Compression Type Cable Gland Size SCU-SCUB-DCU-DCUB Series Cable Gland Size Approx. Min Cable Outer Approx. Max Cable Outer A2F Series – Single Compression Type Cable Gland Size SCU-SCUB-DCU-DCUB Series Cable Gland Size
0.5 3 5.5 6.3 A2F#16; A2F20S 16; 20; 20L 6 2 14.8 15.1 A2F#25 25; 32
0.5 4 5.7 6 A2F#16; A2F20S 16; 20; 20L 6 3 15 16.2 A2F#25 25; 32
0.75 2 6.2 6.4 A2F#16; A2F20S 16; 20; 20L 6 4 16.7 18 A2F#25; A2F#32 25; 32
0.75 3 6.1 7.1 A2F#16; A2F20S 16; 20; 20L 6 5 20.1 20.1 A2F#32 32; 40; 50
0.75 4 7.2 7.8 A2F#16; A2F20S 16; 20; 20L 6 7 20 20.4 A2F#25; A2F#32 32; 40; 50
0.75 7 8 8.7 A2F#16; A2F20L 16; 20L 10 2 20.3 20.3 A2F#32 32; 40; 50
1 2 6.6 8.9 A2F#16; A2F20S; A2F#20L 16; 20; 20L 10 3 21 21.8 A2F#32 32; 40; 50
1 3 7 9.6 A2F#16; A2F20S; A2F#20L 16; 20; 20L 10 4 20 23.8 A2F#25; A2F#32 32; 40; 50
1 4 8 10.6 A2F#16; A2F20S; A2F#20L 16; 20; 20L 10 5 25.7 26.2 A2F#32; A2F#40 40; 50
1 7 8.5 9.3 A2F#16; A2F20S; A2F#20L 20; 20L; 25 10 7 23.2 23.4 A2F#32 40; 50
1.5 2 7.8 10 A2F#16; A2F20S; A2F#20L 16; 20; 20L; 25 16 2 22 22.6 A2F#32 40; 50
1.5 3 8.3 10.7 A2F#16; A2F20S; A2F#20L 20; 20L; 25 16 3 23.8 24.2 A2F#32; A2F#40 40; 50
1.5 4 9.3 11.7 A2F#16; A2F20S; A2F#20L 20; 20L; 25 16 4 23 26.4 A2F#32; A2F#40 40; 50
1.5 5 10 13 A2F#16; A2F20S; A2F#20L; A2#F25 20; 20L; 25 16 5 28.8 29.5 A2F#40 40; 50
1.5 7 10.9 15.4 A2F#20L; A2F#25 20; 20L; 25; 32 25 2 27 27.7 A2F#40 40; 50
1.5 8 15.4 15.8 A2F25 25; 32 25 3 29 29.7 A2F#40 40; 50
1.5 10 15.8 19.4 A2F#25; A2F#32 25; 32 25 4 26.2 32.9 A2F#40; A2F#50S 40; 50
1.5 12 19.5 20.1 A2F#25; A2F#33 32; 40; 50 25 5 31 31.7 A2F#40; A2F#50S 50
1.5 14 20.1 22 A2F#32 40; 50 35 2 32.5 33 A2F#50S 50
1.5 19 23.1 23.6 A2F#33 40; 50 35 3 33 33.6 A2F#50S 50
1.5 24 27 27.5 A2F#40 40; 50 35 4 31.8 32.3 A2F#40; A2F#50S 50
1.5 27 27.5 30 A2F#40; A2F#50S 40; 50 35 5 32.3 33 A2F#50S 50
1.5 30 30 30.5 A2F#40; A2F#50S 50 50 2 38 39 A2F#50S; A2F#50L 63
1.5 37 30.6 31.5 A2F#40; A2F#50S 50 50 3 39 39.5 A2F#50L 63
2.5 2 9.6 11.7 A2F#16; A2F20S; A2F#20L 20; 20L; 25 50 4 43.3 43.6 A2F#50L; A2F#63S 63
2.5 3 10.3 12.5 A2F#16; A2F20S; A2F#20L; A2F#25 20; 20L; 25 50 5 43 44 A2F#50L; A2F#63S 63
2.5 4 11.9 13.8 A2F#20L; A2F#25 20L; 25 70 2 41 42 A2F#50L; A2F#63S 63
2.5 5 12.2 15.3 A2F#20L; A2F#26 20L; 25; 32 70 3 42 42.9 A2F#50L; A2F#63S 63
2.5 7 13.2 17.8 A2F#25 25; 32 70 4 47 47.6 A2F#63S 75
2.5 8 17.8 19 A2F#25; A2F#32 32 95 2 49.5 49.8 A2F#63S 75
2.5 10 19.1 23 A2F#25; A2F#33 32; 40; 50 95 3 49.5 50.1 A2F#63S; A2F#63L 75
2.5 12 23.1 23.3 A2F#32 40; 50 95 4 55.8 56 A2F#63L; A2F#75S 75; 75L; 85
2.5 14 23.3 26.8 A2F#32; A2F#40 40; 50 120 2 53 53.5 A2F#63L 75
2.5 19 26.9 27.5 A2F#40 40; 50 120 3 53.5 54 A2F#63L 75
2.5 24 31.8 32.4 A2F40; A2F50S 50 120 4 59 59.9 A2F#75S 75L; 85
2.5 27 32.4 33 A2F#50S 50 150 2 58 59 A2F#75S 75L; 85
2.5 30 33 36 A2F#50S 50; 63 150 3 59 59.5 A2F#75S 75L; 85
2.5 37 36.8 37.2 A2F#50S 63 150 4 65.5 66.3 A2F#75L 75L; 85; 90
4 2 11 13.6 A2F#20L; A2F#25 20; 20L; 25 185 2 66 66.8 A2F#75L; A2F#90 75L; 85; 90
4 3 11.4 14.6 A2F#20L; A2F#26 20; 20L; 25 185 3 66.8 67.3 A2F#90 75L; 85; 90
4 4 13.5 16.1 A2F#20L; A2F#27 20L; 25; 32 185 4 73 73.8 A2F#90 90; 100; 110
4 5 14.1 18.1 A2F#25 25; 32 240 2 72 73 A2F#90 90; 100; 110
4 7 20.5 20.9 A2F#32 32; 40; 50 240+ Measure Actual Cable Diameter A2F#90 90; 100; 110
4 8 20.8 21.2 A2F#33 40; 50
4 10 21.2 26.3 A2F#32; A2F#40 40; 50
4 12 27 27.8 A2F#40 40; 50
4 14 27.5 28 A2F#41 40; 50
4 19 28 28.5 A2F#42 40; 50

For unarmoured cables, glands are usually single compression or flameproof A2F type. These glands provide sealing but do not require gripping metallic armour.

A2F Single Compression Cable Gland Size Chart

For unarmoured cables, glands are usually single compression or flameproof A2F type. These glands provide sealing but do not require gripping metallic armour.

A2F – Single Compression Cable Glands – Size & Unarmoured Cable Clamping Range
SIZE
Cable Clamping Range (MM)
AVAILABLE ENTRY THREADS
ISO METRIC NPT ET (BSC) BSPP BSPT PG
A2F#16 2.5 – 10 M16 1/2″ 5/8″ G 3/4 G 3/4 PG 9
A2F#20S 2.5 – 10 M20 1/2″ 3/4″ G 1/2 G 1/2 PG 11
A2F#20L 8 – 14 M20 1/2″ 3/4″ G 1/2 G 1/2 PG 13.5, PG 16
A2F#25 12.5 – 20 M25 3/4″ 1″ G 3/4 G 3/4 PG 21
A2F#32 18 – 26.3 M32 1″ 1-1/4″ G 1 G 1 PG 29
A2F#40 24 – 32.2 M40 1-1/4″ 1-1/2″ G 1-1/4 G 1-1/4 PG 36
A2F#50S 30 – 38 M50 1-1/2″ 2″ G 1-1/2 G 1-1/2 PG 42
A2F#50L 38 – 44 M50 2″ 2″ G 1-1/2 G 1-1/2 PG 42
A2F#63S 42 – 50 M63 2″ 2-1/2″ G 2 G 2 PG 48
A2F#63L 50 – 56 M63 2-1/2″ 2-1/2″ G 2 G 2
A2F#75S 55 – 62 M75 2-1/2″ 3″ G 2-1/2 G 2-1/2
A2F#75L 60 – 68 M75 3″ 3″ G 2-1/2 G 2-1/2
A2F#90 66.6 – 80 M90 3-1/2″ 3-1/2″ G 3 G 3

The A2F type is a flameproof gland suitable for unarmoured cables. It ensures safe entry of cables in hazardous zones.

Cable Gland Size Chart Series SCU, SCUB, DCU, DCUB - Size & Clamping Range

The A2F type is a flameproof gland suitable for unarmoured cables. It ensures safe entry of cables in hazardous zones.

Series SCU, SCUB, DCU, DCUB – Size & Unarmoured Cable Clamping Range
SIZE
Cable Clamping Range (MM)
AVAILABLE ENTRY THREADS
ISO METRIC NPT ET (BSC) BSPP BSPT PG
16 2 – 8 M16 3/8″ 5/8″ G 3/8″ G 3/8″ PG 9
20 4 – 12 M20 1/2″ 3/4″ G 1/2″ G 1/2″ PG 11, PG 13.5
20L 5 – 14 M20 1/2″ 3/4″ G 1/2″ G 1/2″ PG 16
25 9 – 17 M25 3/4″ 1″ G 3/4″ G 3/4″ PG 21
32 14 – 23 M32 1″ 1-1/4″ G 1″ G 1″ PG 29
40 20 – 29 M40 1-1/4″ 1-1/2″ G 1-1/4″ G 1-1/4″ PG 36
50 20 – 35 M50 1-1/2″ 2″ G 1-1/2″ G 1-1/2″ PG 42
63 35 – 45 M63 2″ 2-1/2″ G 2″ G 2″ PG 48
75 45 – 56 M75 2-1/2″ 3″ G 2-1/2″ G 2-1/2″
75L 56 – 68 M75 3″ 3″ G 2-1/2″ G 2-1/2″
85 56 – 68 M85 3″ 3-1/4″ G 3″ G 3″
90 62 – 74 M90 3-1/2″ 3-1/2″ G 3″ G 3″
100 68 – 90 M100 3-1/2″ 4″ G 3-1/2″ G 3-1/2″
110 68 – 90 M110 4″ 4-1/2″ G 4″ G 4″
115 84 – 98 M115 4″ G 4″ G 4″
120 84 – 98 M120 4″
130 94 – 114 M130 5″

The SCU, SCUB, DCU, and DCUB series are specifically designed for unarmoured cables, each offering different levels of sealing and mechanical strength.

Cable Gland Size Chart for Armoured Cable

SIZE SELECTION CHART FOR ARMOURED CABLE
Note: These gland sizes may be one size s please measure actual cable size and compare with the minimas sizes in the appropriate glands group
Cable Size (mm2)
No. of Cores
Steel Wire Armouring (SWA)
Cable Size (mm2)
No. of Cores
Steel Wire Armouring (SWA)
Approx Min Cable Bedding Approx Max Cable Bedding ElFW Series Double Compression Type Cable Gland Size DCA-DCAB-SCA SCAB Series Cable Gland Size Approx Min Cable Bedding Approx Max Cable Bedding ElFW Series Double Compression Type Cable Gland Size DCA-DCAB-SCA SCAB Series Cable Gland Size
1 2 8 9.5 E1FW16/20S 16,20/20 10 2 12.3 13.5 E1FW20L 20/25
1 3 9.1 9.6 E1FW16/20S 20/20 10 3 13.1 20.7 E1FW32 20/25,32
1 4 9.5 10.4 E1FW20S 20/20/25 10 4 14.5 16.4 E1FW25S,25L 25,32
1 7 10.2 10.5 E1FW20S 20/25 10 5 17.2 19 E1FW25S,25L 32
1 12 13 13.5 E1FW20L 20/25 10 7 15 20 E1FW32 25,32,40,50
1 19 15.6 16 E1FW25S,25L 25,32 16 2 14.3 15.5 E1FW25S,25L 25,32
1 27 20 20.5 E1FW32 32,40 16 3 15.3 22.8 E1FW32 25,32,40,50
1 37 22 23 E1FW32 32,40 16 4 17 19.8 E1FW25S,25L 25,32
1.5 2 7.3 9.1 E1FW16/20S 16,20/20 16 5 20 21.5 E1FW32 32,40,50
1.5 3 7.8 9.9 E1FW16/20S 16,20/20 16 7 18.1 18.5 E1FW25S,25L 32
1.5 4 8.5 10.9 E1FW20S 20/20 25 2 14 14.7 E1FW25S,25L 20/25,32
1.5 5 9.7 12.3 E1FW20L 20/25 25 3 17.7 24.9 E1FW32 32,40,50
1.5 7 10 14.2 E1FW25S,25L 20/25/32 25 4 20.6 21.5 E1FW32 32,40,50
1.5 8 12.6 15.2 E1FW25S,25L 20/25/32 25 5 24.7 26.5 E1FW40 40,50
1.5 10 14.8 15.4 E1FW25S,25L 25/32 25 7 21 21.5 E1FW32 32,40,50
1.5 12 13.7 15.8 E1FW25S,25L 20/25/32 35 2 16 16.8 E1FW25S,25L 25,32
1.5 14 16.2 17.6 E1FW25S,25L 25/32 35 3 19.3 21.3 E1FW32 32,40,50
1.5 19 16.2 20.5 E1FW32 25/32,40 35 4 21.9 24 E1FW32 32,40,50
1.5 24 21.7 22.4 E1FW32 32,40/50 35 5 27.8 29.5 E1FW40 40,50
1.5 27 20 22.9 E1FW32 32,40/50 50 2 18 19 E1FW25S,25L 32
1.5 30 23.7 23.9 E1FW32 40,50 50 3 21.7 24.2 E1FW32 32,40,50
1.5 37 22.3 26.7 E1FW40 32,40/50 50 4 25 28.1 E1FW40 40,50
2.5 2 8.5 9 E1FW16/20S 20,20/25 50 5 31.8 32.4 E1FW50S 50
2.5 3 9.2 10 E1FW20S 20/20/25 70 2 21 22 E1FW32 32,40,50
2.5 4 9.9 10.6 E1FW20S 20/20/25 70 3 24.7 27 E1FW40 40,50
2.5 5 11.5 13 E1FW20L 20/20/25 70 4 29.2 31.5 E1FW40 50
2.5 7 11 13 E1FW20L 20/20/25 95 2 24.7 25.1 E1FW32 40,50
2.5 8 12 13 E1FW20L 20/20/25 95 3 28.6 31.1 E1FW40 40,50
2.5 10 16 16.6 E1FW25S,25L 25,32 95 4 33.3 36 E1FW50S 50,63
2.5 12 16.3 18.1 E1FW25S,25L 25,32 95 5 42 43 E1FW50L 63
2.5 14 18 19 E1FW25S,25L 32 120 2 27.2 27.9 E1FW40 40,50
2.5 19 19.9 21.4 E1FW32 32,40 120 3 31 33.5 E1FW50S 50
2.5 24 24.7 25.1 E1FW32 40,50 120 4 35.4 40 E1FW50L 63
2.5 27 24 25.7 E1FW32 40,50 150 2 29.5 30.9 E1FW40 50
2.5 30 26 26.6 E1FW40 40,50 150 3 33.9 37 E1FW50S,50L 50,63
2.5 37 26.9 29.4 E1FW40 40,50 150 4 39.3 44 E1FW50L,63S 63
4 2 9.4 11 E1FW20S 20/20/25 185 2 37 37.8 E1FW50L 63
4 3 10 11.5 E1FW20S 20/20/25 185 3 37.8 42 E1FW50L,63S 63
4 4 11 12.5 E1FW20L 20/20/25 185 4 44.5 49 E1FW63S 63,75
4 5 13 14.5 E1FW25S,25L 20/25/32 240 2 41.8 42.6 E1FW50L,63S 63
4 7 12 15 E1FW25S,25L 25/32 240 3 42.6 47 E1FW63S 63,75
4 8 17.3 18.1 E1FW25S,25L 32 240 4 50 55 E1FW63L 75
4 10 19.7 20.2 E1FW32 32,40 300 2 49 49.8 E1FW63S 75
4 12 20.4 21 E1FW32 32,40/50 300 3 49.8 52 E1FW63L 75
4 14 22 22.8 E1FW32 32,40/50 300 4 58 61 E1FW75S 75,85
4 19 24.9 25 E1FW32 40,50 400 2 61 63 E1FW75L 75,85
6 2 10.5 12 E1FW20S 20/20/25 400 3 62.5 64 E1FW75L 75,85,90
6 3 11.2 13 E1FW20L 20/20/25 400 4 64 68 E1FW90 75,85,90
6 4 12.3 14 E1FW25S,25L 20/25/32 400+ Measure Actual Cable Diameter
6 5 14.5 16 E1FW25S,25L 25/32
6 7 13.5 17.5 E1FW25S,25L 20/25/32

For armoured cables, double compression glands are the standard choice. These glands grip both the inner and outer sheath of the cable, ensuring excellent strength and environmental protection.

Double Compression Cable Gland Size Chart & Armoured Cable Clamping Range

E1FW – Double Compression Cable Glands – Size & Armoured Cable Clamping Range
SIZE
Cable Bedding
Diameter
(MM)
Overall Cable
Diameter
(MM)
AVAILABLE ENTRY THREADS
ISO METRICNPTET (BSC)BSPPBSPTPG
E1FW#164 – 9.86.1 – 13.3M161/2″5/8″G 3/4G 3/4PG 9
E1FW#20S164 – 9.86.1 – 13.3M201/2″5/8″G 3/4G 3/4PG 11
E1FW#20S5 – 129.5 – 16.3M201/2″3/4″G 1/2G 1/2PG 11
E1FW#20L6.0 – 13.912.5 – 21.2M201/2″3/4″G 1/2G 1/2PG 13.5, PG 16
E1FW#25S11 – 19.514 – 22.3M253/4″1″G 3/4G 3/4PG 21
E1FW#25L11 – 19.918.2 – 26.7M253/4″1″G 3/4G 3/4PG 21
E1FW#3215.5 – 26.223 – 34.4M321″1-1/4″G 1G 1PG 29
E1FW#4021 – 32.127.9 – 40.8M401-1/4″1-1/2″G 1-1/4G 1-1/4PG 36
E1FW#50S28 – 3835.2 – 47.2M501-1/2″2″G 1-1/2G 1-1/2PG 42
E1FW#50L35.5 – 4440.4 – 53.2M502″2″G 1-1/2G 1-1/2PG 42
E1FW#63S39.5 – 49.945.6 – 59.9M632″2-1/2″G 2G 2PG 48
E1FW/M63L47 – 55.954.6 – 66.2M632-1/2″2-1/2″G 2G 2 
E1FW#75S52.5 – 61.959 – 72.4M752-1/2″3″G 2-1/2G 2-1/2 
E1FW#75L59.1 – 67.966.7 – 78.9M753″3″G 2-1/2G 2-1/2 
E1FW#9066.5 – 79.976.2 – 91.4M903-1/2″3-1/2″G 3G 3 

For armoured cables, double compression glands are the standard choice. These glands grip both the inner and outer sheath of the cable, ensuring excellent strength and environmental protection.

Cable Gland Size Chart Series DCA, DCAB, SCA, SCAB – Size Section Chart

Series DCA, DCAB, SCA, SCAB – Size & Armoured Cable Clamping Range
SIZE
Cable Bedding Diameter
Overall Cable Diameter
AVAILABLE ENTRY THREADS
ISO METRIC NPT ET (BSC) BSPP BSPT PG
16 2 – 8 5 – 13 M16 3/8″ 5/8″ G 3/8″ G 3/8″ PG 9
20 4 – 12 6 – 18 M20 1/2″ 3/4″ G 1/2″ G 1/2″ PG 11, PG 13.5
20L 5 – 14 9 – 19 M20 1/2″ 3/4″ G 1/2″ G 1/2″ PG 16
25 9 – 17 13 – 23 M25 3/4″ 1″ G 3/4″ G 3/4″ PG 21
32 14 – 23 18 – 30 M32 1″ 1-1/4″ G 1″ G 1″ PG 29
40 20 – 29 24 – 35 M40 1-1/4″ 1-1/2″ G 1-1/4″ G 1-1/4″ PG 36
50 20 – 35 26 – 43 M50 1-1/2″ 2″ G 1-1/2″ G 1-1/2″ PG 42
63 35 – 45 42 – 52 M63 2″ 2-1/2″ G 2″ G 2″ PG 48
75 45 – 56 52 – 65 M75 2-1/2″ 3″ G 2-1/2″ G 2-1/2″
75L 56 – 68 65 – 78 M75 3″ 3″ G 2-1/2″ G 2-1/2″
85 56 – 68 65 – 78 M85 3″ 3-1/4″ G 3″ G 3″
90 62 – 74 71 – 84 M90 3-1/2″ 3-1/2″ G 3″ G 3″
100 68 – 90 78 – 102 M100 3-1/2″ 4″ G 3-1/2″ G 3-1/2″
110 68 – 90 78 – 102 M110 4″ 4-1/2″ G 4″ G 4″
115 84 – 98 96 – 110 M115 4″ G 4″ G 4″
120 84 – 98 96 – 110 M120 4″
130 94 – 114 106 – 126 M130 5″

These gland series are widely used for different armoured cable applications and provide secure sealing as per industry standards.

3.5 Core 300 sq mm Cable Gland Size

A frequently asked question in large-scale industrial and infrastructure projects is determining the correct cable gland size for 3.5 core 300 sq mm cable. Since this cable type is classified as a heavy-duty power cable, it demands a gland capable of accommodating a large outer diameter while delivering superior mechanical support and secure sealing.

For a 3.5 core 300 sq mm cable, the most commonly recommended option is a double compression armoured cable gland. This type of gland ensures effective clamping on both the inner bedding and the outer sheath, providing enhanced durability, vibration resistance, and environmental protection.

Typical Specifications

  • Cable Type: 3.5 Core, 300 sq mm

  • Recommended Gland Type: Double Compression (Armoured)

  • Clamping Range: Designed to match an OD of approximately 55–65 mm (may vary depending on manufacturer specifications)

  • Thread Size: Generally M75 or equivalent

 

👉 As cable manufacturers may have slight differences in outer diameter (OD), it is essential to verify the exact dimensions using the armoured cable gland size chart provided by the gland supplier before final installation.

Conclusion

Selecting the appropriate cable gland size chart plays a crucial role in ensuring safe, secure, and long-lasting electrical installations. Whether it involves small indoor wiring systems or heavy-duty industrial power cables, choosing the correct gland guarantees proper sealing, mechanical stability, and overall reliability.

In this guide, we covered:

  • Standard cable gland size in mm

  • Access to downloadable electrical cable gland size chart PDF

  • Complete armoured cable gland size chart and unarmoured cable gland size chart

  • Specific references such as the double compression cable gland size chart and the 3.5 core 300 sq mm cable gland size

 

Using the correct cable gland type and size helps prevent common installation issues such as improper fitting, moisture entry, mechanical stress, and potential electrical failures. Before proceeding with installation, always verify dimensions using the latest cable gland size charts (PDF or manufacturer reference images) to ensure accurate and safe selection.

How to Order Cable Glands from Us

📩 Talk to our technical team today at Exgrip.com

📞 Or call us directly for quick assistance!


Contact Us:

📞 Phone: +91 9537118899

🌐 Website: www.exgrip.com